Unable to login to Data Center Security Server Manager console

I need a solution

I saw this old post and I am having the same problem, although it apears to be the Symantec Data Center Security Server Manager Service that is not running.  Everytime I restart the service it stops after 30 seconds.  When trying to login via the console the following error message appears 'cannot open database "SCSPDB" requested by login.  The login failed.'  Also when checking the event logs on the SCSP server, there is Java Virtual Machine error (with a code of -1 as stated below by Chuck) for the SISManager.  When I check the event logs on the SQL server there are failure audits, Source: MSSQL$SCSP, Event ID: 18456, login failed for user 'SCSPDBA' (Client:*.*.*.*).  I'm no SQL or SCSP guru, our usual tech is on holiday so any help would be grealty appreciated.

https://www-secure.symantec.com/connect/sites/defa...) 100% -45px no-repeat transparent;">Chuck EdsonSYMANTEC EMPLOYEEACCREDITEDCERTIFIED

Muydess is correct.  

If the SCSP Server Service will not stay running, then check the Windows Event Logs for a Java -1 error.  If you find that, then let us know, there are several things that can cause the java -1 situation (database connection/password incorrect, out of transaction log space, database/instance not running, corruption of server.xml file or catalina properties).

Note that it can take up to 30 seconds for the service to timeout and show that it is stopped -- so start the service, wait a little, then refresh the services.msc window.


Viewing all articles
Browse latest Browse all 278

Trending Articles



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>